We started by pulling a ton of Cat 5 runs in through our shop for a demo unit we’re building. I mainly work with Cat 5, so the alligator clamps are what I turn to most frequently. The toner includes a pair of alligator clamps and an RJ-11 connector for terminated phone jacks. If you’re not sure what mode you’re in, take a peek at the LED-it matches the mode (constant, flashing, off).įlip the switch to ‘”cont” to check continuity. Start with the switch in the “tone” position and press the button on the left to cycle between constant, alternative, and power off. You can choose between constant and alternating tones. It’s strong enough to send a tone up to 10 miles down the line on many cables. Looking at the Fluke Networks Pro3000 Toner, there are 5 different tones you can send to dial in the exact pair you’re identifying. When you don’t want or need to use headphones, the built-in speaker is plenty loud enough for general identification. Just plug in a set of headphones or earbuds and let your ears hone in better. The Fluke Networks Pro3000F60 (and Pro3000 analog) have a 3.5 mm jack on the side. Ambient noise from work going on around you doesn’t help. When you’re working around cable or wire bundles, it can be challenging to figure out exactly which wire the tone is on.

#Fluke network inspector 4.1 pro

Pro Tip: The LED doesn’t light up and the volume decreased when your battery is close to dead.Įven though there’s a filter, you still need to use this on an inactive line. If you don’t want to use, press the button and it turns red to let you know it’s off. When you turn the probe on, a green light lets you know that the filter is also on. Here in the US, we’re on a 60Hz system, so our Pro3000F is set to filter out that frequency. The Fluke Networks Pro3000F60 (or Pro3000F50 in 50 Hz areas) filters out the extra noise to make it easier to identify or trace your line amongst others. While the toner sends a clearly different signal from all that, the additional noise can make it difficult to identify which wire actually has the tone in it. With a traditional tone and probe set, any live wires send a signal that the probe can pick up. Whether it’s because your hearing isn’t what it used to be, you work around challenging cable bundles, or you’re just trying to make the job easier, I can highly recommend this kit for cable and wire identification. For the communications installs I do, it functions beautifully. 1010.The big draw for the Fluke Networks Pro3000F60 Tone and Probe Kit is its ability to filter. Tone characteristic is changed as cable condition changes to “normal-open” from any other condition. Indicator flashes when battery voltage falls below 4.1 VĪpproximately 1 kHz at an amplitude of 80 % of battery voltage. Time Domain Reflectometry (TDR) with 50 Ω drive impedance, 6 V maximum pulse height Default to -66- when batteries are changed Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity.Īdjustable from -20- to -99-, retained during power off. ☒ feet for cables less than 10 feet ±5 feet for cables longer than 10 feet and shorter than 200 feet ☓ % and ±5 feet for cables longer than 200 feetĪn ac voltage of more than 5 V rms will trigger the High Voltage Warning. No minimum length Minimum non-zero reading is 2 feet

#Fluke network inspector 4.1 tv

The tester will display –Err if the cable is too long to be correctly measured.Ģ500 feet: CAT-5 Twisted Pair 2000 feet: 12/2 ac Wire 1000 feet: RG-6/U TV Coax 500 feet: RG-174/U Coax Cables with an impedance outside this range will not be properly tested and may produce erratic or incorrect readings.Ģ500 feet on certain cable types, 2000 feet on most cable types, and 500 feet on very lossy cables. See the information on moisture under “Maintenance”.ģ5 Ω to 330 Ω with auto-compensation within this range. If the tester is exposed to water, some may get inside, but it will suffer NO DAMAGE.

fluke network inspector 4.1

No damage to the tester will occur if the batteries are installed backwards. 4 AA alkaline batteries, provide 50 hours of operation.